Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Organ Transplantation ; (6): 66-2020.
Article in Chinese | WPRIM | ID: wpr-781856

ABSTRACT

Objective To investigate the rationality and efficacy of enhanced recovery after surgery (ERAS) in liver transplant recipients. Methods Clinical data of 465 liver transplant recipients were retrospectively analyzed. All recipients were divided into the ERAS group (n=163) and control group (n=302) according to whether they received ERAS. The severity of disease in the ERAS group was worse than that in the control group. Operation situations including the operation time, anhepatic phase and intraoperative blood transfusion volume of the liver transplant recipients were observed and recorded. Postoperative recovery conditions including the length of intensive care unit (ICU) stay, total length of hospital stay, total ventilator removal time at postoperative 28 d and postoperative re-intubation rate were recorded. The survival rates at 90 d, 180 d and 1 year after liver transplantation were calculated. The influencing factors of survival rate of liver transplant recipients were analyzed. Results The anhepatic phase in the ERAS group was 45 (39, 53) min, significantly longer than 40 (32, 48) min in the control group (P < 0.05). The volume of erythrocyte infusion in the ERAS group was 10 (7, 13) U, significantly less than 18 (10, 28) U in the control group (P < 0.05). The length of postoperative ICU stay and total length of hospital stay in the ERAS group were 135 (84, 212) h and 24 (18, 33) d, significantly shorter than 154 (103, 253) h and 34 (20, 50) d in the control group (both P < 0.05). Total ventilator removal time at postoperative 28 d was 26 (25, 27) d, significantly longer than 26 (23, 27) d in the control group (P < 0.05). The postoperative re-intubation rate in the ERAS group was 11.0%, significantly lower than 20.8% in the control group (P < 0.05). The 90 d, 180 d and 1-year survival rates in the ERAS group were 92.8%, which were significantly higher than 81.1%, 78.1% and 75.7% in the control group (all P < 0.05). ERAS and operation time were the independent influencing factors of survival rate of liver transplant recipients (both P < 0.05). Conclusions ERAS after liver transplantation can improve the survival rate of recipient, shorten the length of hospital stay, reduce the re-intubation rate and accelerate the rehabilitation after liver transplantation.

2.
Organ Transplantation ; (6): 41-2020.
Article in Chinese | WPRIM | ID: wpr-781852

ABSTRACT

Enhanced recovery after surgery (ERAS) refers to adopting a series of perioperative optimization measures to prevent or reduce the inflammatory stress response, promote rapid postoperative recovery of patients, shorten the length of hospital stay, reduce the incidence of postoperative complications, readmission rate and mortality rate. As the only effective treatment for end-stage liver disease, liver transplantation is characterized with difficult operation, long operation time, large amount of blood transfusion during operation and complicated postoperative management, etc. Postoperative recovery of liver transplantation is facing great challenges. In this article, research progresses on the application of ERAS in the perioperative period of liver transplantation and the suggestions for the implementation of ERAS during this period were introduced.

3.
Organ Transplantation ; (6): 378-381, 2015.
Article in Chinese | WPRIM | ID: wpr-731607

ABSTRACT

Objective To summarize the treatment experience of sepsis after liver transplantation.Methods The clinical features and treatment methods of 1 patient developing sepsis after liver transplantation, who was admitted and treated in the Surgical Intensive Care Unit of the Third Affiliated Hospital of Sun Yat-sen University in September 201 4,were retrospectively studied.The interpretation of International Guidelines for Management of Severe Sepsis and Septic Shock (SSC Guidelines)and relevant literature were reviewed.Results One male patient at the age of 50 years old developed high fever and decrease of blood pressure at 1 d after liver transplantation,and was diagnosed as septic shock.The symptoms were relieved after the appropriate treatment like goal-directed fluid resuscitation,anti-infection and blood purification,etc.And the patient was discharged in stable conditions.Conclusions It is easy to develop infection after liver transplantation and the fatality rate of sepsis caused by infection is high.Once the sepsis occurs,clinicians must perform early goal-directed therapy and bundle therapy according to the SSC Guidelines positively,and select the appropriate drugs according to the pathogen culture results in order to reduce the fatality rate.

4.
Chinese Journal of Tissue Engineering Research ; (53): 5607-5612, 2013.
Article in Chinese | WPRIM | ID: wpr-433732

ABSTRACT

BACKGROUND:The mechanical valves used in the adult Luo-Ye pump have a large size and great destruction to blood, which are not suitable for infant ventricular assist pump. Therefore, designing and producing a high molecular valve with smal size and low incidence of thrombosis is a research hotspot. OBJECTIVE:To design and produce a valve of 20 mL infant Luo-Ye pump, and to test its basic functions and fatigue properties. METHODS:The size and shape of valve was designed with MASTERCAM software, polyurethane valve was obtained through producing the valve model and plastic injection;the static leakage, pressure drop and fatigue resistance of polyurethane valve were tested according to the ISO5840 requirements. RESULTS AND CONCLUSION:The polyurethane trefoil valve was produced, but the failure rate of plastic injection was high;the basic function of the trefoil valve met the ISO5840 requirements bascial y;after continuously operated 1.0×107 times, stroke volume of 20 mL Luo-Ye pump was changed 5.2%, and two polyurethane valves and valve leaflets did not change and damage. Polyurethane trefoil valve was designed and produced successful y;polyurethane valves could meet the needs of 20 mL Luo-Ye pump, which already have the ability to clinical trials.

SELECTION OF CITATIONS
SEARCH DETAIL